Assessment of fire-resistant panels for air conditioning ducts

Assessment of fire-resistant panels for air conditioning ducts

A manufacturer of panels with fireproof properties intends to use them to assemble HVAC and smoke conduction ducts, but the composition of these products places them outside the scope of application of the European harmonized standards. ITeC has checked whether the EAD Guide 350142 covers this type of panels and has assisted the manufacturer in the preparation of the Technical Dossier and the Control Plan, and during the subsequent laboratory tests. The final step has been the issuance of a European Technical Assessment.

2022 - 2023|Private client
Life Cycle Analysis of a domestic ventilation system

Life Cycle Analysis of a domestic ventilation system

A Life Cycle Analysis (LCA) has been carried out on a ventilation and filtering system with heat recovery targeted at the housing market. The documentation provided has allowed the manufacturer to issue a “cradle to gate” self-declaration in accordance with UNE-EN 14804+A2 standard.

2021 - 2022|Private client
Evaluation of HVAC ducts built with mineral wool boards

Evaluation of HVAC ducts built with mineral wool boards

The EN standards that regulate mineral wool do not cover the case of HVAC ducts built with this kind of boards, so they can not be CE-marked. An EAD document has been developed, enabling the possibility for this type of ducts to get a CE mark if they are backed by an ETA that substantiates their satisfactory thermal performance, safety in case of fire, acoustic behaviour and durability, among others.

2021 - 2022|Private client
Documentary, budgetary and legal compliance check of the renovation of the HVAC system in a health facility

Documentary, budgetary and legal compliance check of the renovation of the HVAC system in a health facility

Before tendering the renovation of the air conditioning system of a healthcare building, a preliminary examination of the executive project has been carried out. It contemplates the replacement of the current equipment with variable refrigerant volume units featuring heat recovery, with the additional difficulty of keeping the existing ventilation and electricity systems. The project assessment has identified some conflicts derived from the complexity of the operation, in which 8 heat pumps and 77 indoor units will be installed.

2017|Private client
Assessment of air renewal mechanical systems

Assessment of air renewal mechanical systems

Assessment of a mechanical ventilation system for non-residential buildings in relation to the indoor air quality and thermal efficiency criteria of the Spanish CTE building code and RITE regulations for HVAC. These systems perform a continuous measurement of the internal CO2 level and self-regulate the airflow rate towards the room accordingly. It includes a method to calculate the number and size of the equipment that guarantees air renewal in each space with the least possible energy loss.

2013 - 2015|Private client
Identification of the causes of corrosion in the pipes of a heating system

Identification of the causes of corrosion in the pipes of a heating system

The heating system in a public building of recent construction shows an abnormally advanced phenomenon of corrosion in its pipe network, and different factors are being considered as a cause: inadequate choice of pipe, excess air in the pipes from an inefficient deaeration, and biological corrosion by bacteria.

2013|Public client
Identification and analysis of the European assessment requirements applicable to cold rooms

Identification and analysis of the European assessment requirements applicable to cold rooms

Characterization of the components used for assembling modular construction cold rooms (sandwich panels, substructures, doors and ancillaries for assembly and sealing) with respect to the requirements of thermal insulation, air permeability, fire safety, safety in use and hygiene. It has also addressed the issues of maintenance, repair and cleaning.

2008 - 2010|Private client
Criteria for the design and installation of fireplaces and chimneys in timber frame buildings

Criteria for the design and installation of fireplaces and chimneys in timber frame buildings

Good practices and safety criteria for installing fireplaces for solid fuels in single-family wood-frame buildings, covering the usual box fireplaces in the market, either freestanding or inserts. Guidance on the correct location, condition of the base and the contiguous walls, air intake, geometry of the chimney and caps.

2009|Private client
Regulatory framework for plastic chimney systems

Regulatory framework for plastic chimney systems

At the time of writing this report, the EN 14471 standard was still in a preliminary phase and the Spanish code for installations was awaiting a new revision. As a result, chimneys and smoke ducts made with plastic materials were left in a situation of legal ambiguity. In these circumstances, the manufacturer was informed of which were the options available to present technical evidence of the proper functioning of his systems, mainly in the field of voluntary certification.

2004|Private client
The heating market in Spain

The heating market in Spain

Market research on boilers and hot water production, measuring consumption in volume and value in a series of product types according to the type of fuel, power and features. It includes historical series and forecasts based on the trends of the demand and the building rules, and market shares of the leading players.

2004|Private client